I founded energyconsumption.org and the EC Users' wiki. I own several watt meters and have plugged them into many devices. I haven't written everything down, but these sites are helping me share my finds.

 


April 2011

After PG&E mailed me a 15-day warning notice, I logged in to pay my bill.  It was a dime short of $150 -- and covered gas and electricity (and ClimateSmart charges) for 7 months.  That's still more than $20/mo and our house still isn't properly sealed or insulated. :P

 

The big news from the pge.com login is that our SmartMeterâ„¢ is finally hooked up!  In fact, it was hooked up in early February, but I missed out on that special gift because I was too lazy to pay our bill regularly.

 

The web site says our effective daytime idle on medium-warm days is 40W.  The floor as read by the meter itself is has lately been 11W (--sleepingPPCMachines).  The fridge should be the only dynamic load when we're not around.  And that 30W-40W depending on temperature matches the 20-30 kWh/mo I've measured for the past several years.  To double-check a single day, I suppose I could record the meter's kWh count and zero the kWh counter on the fridge before leaving for work.  In the evening, I'd check compare the fridge's consumption with the day's delta on the meter.  11W * 8 hours + fridgeEnergy should come out to ~40W (current web site value) * 8 hours on the meter.

 


January 2011

I've had several questions about my "Internet Timer."  The timer is primarily a social tool for our household's ability to focus, but it started as an energy-saving project and it highlights the energy savings opportunities of sleep and away times.  Thanks to Keith for the prod to post the writeup.

 

We have two shutoff mechanisms (both mentioned on Projects).

 

One is a simple X-10 switch which we use to remotely turn the Internet access equipment on and off.  This adds overhead to having Internet access and forces us to be conscious of when we're using it vs. not.  In our practice, this mostly serves to save energy on networking equipment during the day when we're not home.

 

The other mechanism is a 7-day programmable timer.  It limits when the X-10 switch is capable of being turned on.  It generally allows Internet access during the day but it (currently) cuts off Internet access from 10:30pm to 5:30am.  It also limits Internet access during the day on Saturdays and in the mornings to ensure I take a shower even if I get up early and start working online.  In our practice, the timer primarily keeps us the off Internet at night (while also saving energy if we forget to use the X-10 switch to turn it off).

 

After I replaced the ~12W of DSL modem and AirPort base station with a ~6W combined unit from NetGear, the control equipment is starting to consume a significant fraction of the power being switched.  The original inspiration for the timer was to reduce the leakage on the X-10 receiver, but the timer is warmer than the X-10 receiver.  In the end, keeping the Internet equipment off when we're not using it is a win, but it's important to be aware of the power costs of control equipment.  For example, putting X-10 in every outlet would let you control everything, but you'd also have a high constant power drain due to the X-10 equipment's phantom draw.

 


Early 2010

As noted below, we now have a Smart Meter with digital readout.  Here is my initial guess at where the 13W it reads at "house idle" are going:

- 2W to the X-10 controller used to switch the DSL+802.11 Internet device on and off (only saves 6W? :P)

- 2W to the "Internet Timer" that cuts power to the X-10 switch / limits when we use the Internet

- 1W to the doorbell transformer

- 1W to the motion/daylight sensor on the garage light

- 3W to the answering machine/cordless phone combination (older Energy Star model)

- 4W to two sleeping ppc laptops?

- I forgot the watt meter on the fridge ... it will be fun to figure out the real values (and amusing when they don't add up because of the weird power factors :).

 


9 March 2010

Good news ... I may end up with efficient ventilation and efficient heating after all!

 

Here's what happened this morning.

The friendly folks at the nearby Built-In Center have all their stuff set up to be plugged in.  So it was easy for me to plug my watt meter (in this case a Kill-a-Watt EZ with the required "liberator" for easier reading) into the heat/light/fan unit I had reconciled myself to buying.  Unfortunately, the NuTone 9427 (supposedly identical to the Broan 164 mentioned yesterday) had an exhaust fan that consumed 50W with 123VA of "slosh" (i.e. not at all correctd for power factor). Even the tiny "cooling fan" for the heat lamps drew 17W. :P

 

I explained how sad I was that I couldn't get a heat lamp + fan with an Energy Star motor.  I asked whether the one that came without a ventilator could be hooked up to an external fan.  That one didn't have a vent, but they were happy to sell me the vented fixture without its "crummy old motor" (saleman's words :). The guy didn't think they had any Energy Star "external/inline" fans but when I mentioned FanTech, he showed me the display and noticed the Energy Star logo.  He immediately started asking his partner which model fan had compatible-sized ductwork.

 

Off went the salesman to get the boxes from the back room.  Even while looking up prices for us, his partner was more than happy to answer my questions about controls.  Out came the boxes, out came the various parts, and off came the "crummy old motor."  I only paid for what I took: they'll order another external fan part (and bracket) to put that kit back together and they'll sell the motor I didn't want as a spare part.  "Everything's here' to sell," the salesman said, "so we're happy to give you what you want."  I was more than happy to pay the contractor price (since my contractor had sent me over :).

 

The electricians may charge extra to install it or I may have to do it myself ... but either way, I'm hoping this all works out.


8 March 2010

(need to move some of this data to a new Ventilation page; the rest to Heating)

The electricians are now waiting on lighting circuit(s?) for me to procure a heat/light/fan for the bathroom. I would like to get one that is Energy Star rated but my desire for a heat lamp (250W vs. 1000-1500W heater) has been complicating the effort.  Energy Star's ratings demand 1.4 cfm/W for smaller fans and 2.8cfm/W for larger fans.  They exclude heat lamp units (?) -- perhaps because installing one incorrectly could leave you getting all your light from a very inefficient bulb?  Or maybe they're not such a good idea.

 

Fan efficiency/power data thus far:

 

  • 55W for my existing uncleaned, un-oiled fan (no idea it's CFM rating; guessing ~70)
  • what appears to be 50W extra for the fan portion of the Broan 162 (70 cfm => 1.4 cfm/W)
  • what appears to be 45W extra for the fan portion of the Broan 164 (70 cfm => 1.55 cfm/W); it also delivers 85% of its throughput all the way up to .4 "in-wg" of static pressure
  • The Energy Star rated Fantech 100 delivers 100 cfm for only 19W (5.26 cfm/W)!
  • Panasonic has a variety of fans that deliver 3.5-4.5 cfm/W (FV-08VQ3 looks about right)
  • Broan's Energy Star fans provide no specs on their fan energy consumption :P 

 

Assumptions / Calculations

 

  • the heat function would operate 20 minutes / day, 4 months of the year (40 hrs/yr; 10 hrs/cool mo)
  • the ventilation function would average one hour / day, 12 months a year (365 hrs/yr)

 

 

Calculations

 

  1. forced-air heat: 40 hrs * 1500W = 60 kWh/year or 15kWh/mo during cooler months
  2. radiant heat: 40 hrs * 250W = 10 kWh/yr or 2.5 kWh/cool mo 
  3. double-radiant heat: 40 hrs * 500W = 20 kWh/yr 
  4. inefficient ventilation: 365 hrs *  45W = 16.5 kWh/yr or 1.4 kWh/mo
  5. efficient ventilation: 365 hrs * 25W =  9.1 kWh/yr or .76 kWh/mo
  6. #1 + #4 =  ~70 kWh/yr
  7. #2 + #3 = < ~30 kWh/yr 

 

 

Conclusions

  • Inefficient ventilation wastes less energy than inefficient heat :P
  • But why can't I have both? 

 

Controls

 

Should we go for a wall-mounted fan in the kitchen? 

 

  • Panasonic WhisperWall FV-08WQ1 delivers 70 cfm for 

 

 

Comments... 

Have you thought about an energy recovery ventilator?  This recovers the heat from the exhaust.  The problem being, the CA climate doesn't make them particularly useful, especially moreso when you already use as little energy as you do, and when you have relatively wide comfort standards.

-Skander

 

I was pleased to find several ERV's in the catalogs and web pages for various vents and such.  I have yet to hear of someone resealing an older house so well that it would require an ERV.  But sucking air out of the bathroom will suck it in somewhere else and the outside morning air is sometimes (but not usually!) the wrong temperature.

 

Could you post something on the Ventilation page about how ERVs work and what climate is best and why?  In Northern California's Mediterranean climate, it is damp and cool at the same time.  Does the ERV like moist air or dry?  Obviously moist air takes more energy to heat.  Answer there, not here. :)

 

Because we've had no timer on the fan, we've generally just left the window open after showering.  During the heating season, we'll probably leave the window closed and fan off until afterwards.  The rest of the year, we'll just have the window open (and the dry air will do most of the hard work anyway :P).

 

 


6 March 2010

I'm pretty excited to have a smart meter on the side of my house.  I haven't even looked to see what sort of feedback PG&E is offering online, but it cycles through 6 readouts every 18 seconds and today I used it to measure the consumption of the fan in the bathroom.  Just after the fridge turned off, I took the bulb out (there's a single switch for fan+bulb; that will be fixed soon! :) and then went outside to establish baseline (18W w/Internet on!) followed by having the fan running (~73W).  That's 55W for my current bathroom fan.  Definitely worth having on its own switch/timer and probably worth beating when I replace it with what I hope will be a fan/heat lamp/light unit this week.

 

Why this week?  Because I'm finally be getting the house rewired.  Mostly, it paves the way to getting wall and under-house insulation which I have needed for years.  It is also an opportunity to install a whole house meter, ideally one with multiple channels so I can monitor several different areas of the home independently.  I feel like some of the meters (Brultech? the new TED) offer some amount of multi-channel functionality, but I don't have details yet and need to place my order soon!  As a bonus, the owner of Voltz Electric (yes, with a 'z' :) even seems interested in energy awareness and conservation technology as a way to grow his business.  I need to put together an Electricans page to give him and others some ideas about how to compete as the most effective at reducing energy costs!

 


27 December 2009

I noticed that we're paying PG&E 11.531 cents/kWh which is, I believe, slightly higher than before (this is before the nominal -- 0.254 cents/kWh -- ClimateSmart charges but includes generation, distribution, taxes, etc).  I'd noticed the top-tier rates going up (beyond 40 cents/kWh), but not so much the rates at the baseline.  This is even as my church (a business customer) got a letter saying it would receive a one-time credit on its electric bill because gas has gotten so cheap (and indeed, my same December bill shows gas at a seasonally-low $1/therm).


 

Last weekend (11-12 August, 2007) I finished my microwave hack (mentioned on Projects). Today (20 August 2007) I am powering off a laptop that has been asleep in my house for almost two years:

 

ansel.local:/Users/slimer=> uptime

17:20 up 506 days, 4:55, 4 users, load averages: 0.40 0.37 0.48

I may bring this machine back up to the sleep state if I have need for it, but in the meantime, it's finally getting shut off.

 